NX-1200 Specifications

NX-1200 Specifications
Dimensions (HWD):
Active Power
Requirements:
Active Power
Consumption:
Memory:
Weight:
Enclosure:
Certifications:
Front Panel Components:
Program Port:
USB Port:
Configuration DIP
Switch:
Master LEDs:
Serial LED
(red / yellow):
IR LED (red):
IRRX LED (red):
Digital I/O LED
(yellow):
IRRX Port:
ID Pushbutton:
Hardware Reference Guide - NX-Series NetLinx Integrated Controllers
1.645" x 5.8" x 5.15" (41.78mm x 147.32mm x 130.81mm)
RU: 1/3
• DC input voltage (typical): 12 V
• DC current draw: 200 mA @ 12 V
• DC range, voltage: 9-18 V
DC
3W
• 512 MB DDRAM
• 1 MB Non-volatile RAM (NVRAM)
• 4 GB Internal MicroSD memory card
1.6 lbs (0.7257 kg)
Metal with black matte finish
• FCC CFR Title 47 Part 15
• CE EN 55022
• CE EN 55024
• CE EN 60950-1
• IEC 60950-1
• UL 60950-1
• C-Tick CISPR 22
• IC CISPR 22
• VCCI CISPR 22
• RoHS / WEEE compliant
1 Type-B USB port that can connect to a USB port on a PC and access the NetLinx
Studio program for controller configuration.
1 Type-A USB port for connecting a mass storage device for loading .tkn files, reading
or writing configuration files and log files, or updating the firmware on the unit.
The Configuration DIP Switch allows you to set boot-time operations (see the
Configuration DIP Switch section on page 30 for more information.)
• LINK/ACT (green): Blinks when the Ethernet cables are connected and terminated
correctly. Also blinks when receiving Ethernet data packets.
• STATUS (green): Blinks to indicate that the system is programmed and
communicating properly.
• OUTPUT (red): Blinks when the Controller transmits data, sets channels On and Off,
sends data strings, etc.
• INPUT (yellow): Blinks when the Controller receives data from button pushes, strings,
commands, channel levels, etc.
2 sets of LEDs light to indicate that RS-232 ports 1-2 are transmitting or receiving
RS-232, 422, or 485 data (red = TX, yellow = RX).
2 LEDs light to indicate the IR/Serial ports 11-12 are transmitting control data. LED
indicator for each IR port remains lit for the length of time that IR/Serial data is being
generated.
1 LED light to indicate the IRRX channel is receiving control data via the IRRX port. The
LED indicator remains lit for the length of time that IR data is being received.
Lights when I/O channels 1-4 are active. The LED for each I/O port reflects the state of
that particular port.
1 1/8" mini-phono connector for interfacing with an IR03 IR receiver.