Upc20+ Wiring Requirements; Specifications - AMX UPC20 Plus Operation/Reference Manual

Universal power controller
Hide thumbs Also See for UPC20 Plus:
Table of Contents

Advertisement

Specifications

UPC20+ Specifications
Power
Power input (for control board)
Power output per relay
Maximum operating ambient
temperature
Approvals
Includes
Inputs
Control Ports
Input Power Switch (S1)
High Voltage Terminal Block (P1) High voltage input and output wiring for motor or power control.
Low voltage and Control
Terminal Block (P2)
Jumper JP1
Test Switches (PB1 and PB2)
Motor Time Delay Potentiometer
(R8)
DIP Switch (S2)
Enclosure
Dimension (HWD)
Weight
Options
UPC20+ Universal Power Controller
Self-powered when used with 110/220 VAC
~
120/240V
, 50-60 Hz, 0.05/0.025A
-or-
12 VDC, 0.2A max
~
• 20A @ 120/240V
, 50-60 Hz (RESISTIVE LOAD)
~
• 6A @ 277V
, 50-60 Hz (FLUORESCENT BALLAST)
~
• 1 HP @ 120V
, 50-60 Hz (INDUCTIVE LOAD)
~
• 2 HP @ 240V
, 50-60 Hz (INDUCTIVE LOAD)
Total Current through both relays CAN NOT exceed 20 amp.
55°C
UL / C-UL / CE
• 1-, 2-, and 3-button logic modes
• Local test switches with status LEDs
• 120, 240, and 277 VAC control capability
• 4 closure inputs, operation defined by mode.
• One IR remote sensor input.
• Motor Control mode alternates between the timed operation of the two
power relays.
• Power Control mode allows independent control of both power relays.
Two 2400 W power relays. Total combined current through both relays is 20
Amps.
• Set this switch according to the high voltage wiring that will be connected
to terminals 5 and 6 on P1. Refer to theP1 Terminal Connections section
on page 7.
• Set switch S1 to the line input voltage value used before applying power to
the UPC20+.
Contact closure, open-collector or CMOS logic level remote control wiring.
Inputs 5 - 8 are referenced to the common connection at pin 4.
Sets control mode of the unit to contact closure or remote sensor serial
data.
Provides local operation of relays K1 and K2 for testing power circuits or
motors connected to the relay terminals. An LED indicates relay power
applied.
Only used in motor control modes. User adjusted for setting relay release
time between 0 and 90 seconds.
Provides selection of control mode options. See Motor Control Mode DIP
Switch S2 Positions table on page 4 and Control Input Wiring to Connector
P2 Terminals table on page 4 for control mode settings.
Metal with black matte finish, knockouts for conduit.
• 8.5" (10.5" including flange) x 4.5" x 2.2"
• (220 mm (270 including flange) x 110 mm x 60 mm)
3.0 lbs. (1.4 kg) with flange
12 VDC power supply (for 277 VAC applications)