FUNCTIONAL DESCRIPTION
NOTE: All function adjustments will be auto-
matically accepted 15-seconds after pressing
a given touch zone or button. The user may
press the MODE/SET button to immediately
accept the adjustment manually.
MODES OF OPERATION
OPERATION MODES:
MANUAL OFF
MANUAL ON
THERMOSTAT (with optional PRO-
GRAM Mode)
The modes may be cycled in the order above
by touching the MODE Zone or pressing the
MODE/SET Button.
MANUAL OFF MODE:
Transmits fl ame OFF command.
Pilot Method: Intermittent Pilot Ignition
(IPI)/Spark-to-Pilot only (continuous/
standing pilot not allowed)
Pilot fl ame will be turned OFF
LCD Displays:
MODE Zone: OFF is displayed
ROOM TEMP Zone: Measured tempera-
ture is displayed
SET TEMP Zone: Blank
TIME/PROG Zone: Current day indicator
and current time is displayed
FLAME Zone: Blank
900719-00C
OPERATION
Continued
MANUAL ON MODE:
Transmits fl ame ON command.
Pilot Method: Intermittent Pilot Ignition
(IPI)/Spark-to-Pilot only (continuous/
standing pilot not allowed)
Pilot fl ame will be ignited before turn
Main Flame ON.
LCD Displays:
MODE Zone: ON is displayed
ROOM TEMP Zone: Measured tempera-
ture is displayed
SET TEMP Zone: Blank
TIME/PROG Zone: Current day indicator
and current time is displayed
FLAME Zone: A Flame Icon and fl ame
setting level number is displayed
THERMOSTAT MODE:
Will cycle fl ame on and off based on
room and set temperatures. Will transmit
ON command if SET TEMP (+SWING)
is higher than ROOM TEMP and will
transmit OFF command if SET TEMP
(-SWING) is lower than ROOM TEMP.
Built-in thermostat will measure room
temperature.
All programming should be written for
deg. F and converted to deg. C when
selected.
Temperatures may be displayed in
degrees F (factory default) or degrees
C. Press the UP and DOWN Buttons
simultaneously to change between
degrees F and C.
SET TEMP: While in THERMOSTAT
mode, press the UP or DOWN Button
to change the SET TEMP (45-90 deg. F,
7-32 deg. C); the new set temperature
will automatically be accepted after 2
seconds. The factory default SET TEMP
is 68 deg. F.