Wiring Connection - LG AUUW096D Installation Manual

Table of Contents

Advertisement

Wiring Connection

• Open the control box cover and connect the Remote controller cord and Indoor power wires.
Terminal Block of Outdoor Unit
1(L) 2(N)
POWER INPUT
The power cord connected to the outdoor unit should be
complied with the following specifications (This equipment shall
be provided with a cord set complying with the national
regulation).
NORMAL CROSS-SECTIONAL AREA
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent.
W
ARNING:
Make sure that the screws of the terminal are free from looseness.
1(L) 2(N) 3
CAUTION
MODEL
1 Phase
AUUW096D
1.5mm
2
[UU09W ULD]
AUUW126D
1.5mm
2
[UU12W ULD]
AUUW186D
2.5mm
2
[UU18W UED]
AUUW186D1
2.5mm
2
[UU18W UED1]
Terminal Block of Indoor Unit
1(L)
2(N)
3
The connecting cable connected to the indoor and outdoor
unit should be complied with the following specifications
(This equipment shall be provided with a cord set complying
with the national regulation).
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
Wiring Connection
2
Installation Manual 29