5. Wiring Connection

• Open the control box cover and connect the Remote control cord and Indoor power wires.
Control box cover
fitting screw (4 units)
ö
Heat Pump Model
§ §
Terminal Block of Indoor Unit
3(N) 4(L)
ö
Cooling Model
§ §
Terminal Block of Indoor Unit
3(N) 4(L)
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR
or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or its service agent.
WARNING
Make sure that the screws of the terminal are free from looseness.
5
6
7
5
6
7
CAUTION
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
9
Remote control
cord
Indoor Power wires
Control
box cover
[Air inlet side view]
Wire taking inlet
Terminal Block of Outdoor Unit
1(N) 2(L)
3(N) 4(L)
Power Cord
Terminal Block of Outdoor Unit
1(N) 2(L)
3(N) 4(L)
Power Cord
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
5
6
7
8
5
6
7
8