8. Remove burner by removing 2 screws at the back of the burner in
locations shown below.
Diagram 5 - Burner Screw Locations
9. Pull off the pilot cap to expose the pilot
orifi ce (see right).
.
10
Unscrew the pilot orifi ce with the Allen key and replace
with the LPG pilot orifi ce in the kit and replace pilot cap
(see right).
11. Remove burner orifi ce with a 12mm spanner and discard. Use
another spanner to hold on to the elbow below the orifi ce.
32
919-131a
Pilot Cap
Pilot Orifi ce
Diagram 4 - Remove Pilot Cap
12. Reinstall new burner orifi ce LP stamped #53 or ULPG burner
orifi ce stamped #53 and tighten.
13. Replace the yellow "NG" label with the red "ULPG" label.
14. Carefully pull out the control box.
NOTE: The control box is held in place with velcro.
15. Remove the heat shield from the control box by removing the 2
screws.
16. Remove the control box cover by undoing the 3 screws.
Manoeuvre through antenna.
17. Remove the jumper using pliers.
Jumper
18. Reverse steps 15-14, for both units.
19. Adjust the air shutter opening (See page 33 for Aeration Adjust-
ment).
For GF900C reverse steps 8-6 and 1.
For GF900L reverser steps 5-1.
20. Turn on gas supply and plug in power cord.