Kohler ESCALE K-25091T-S Installation Instructions Manual page 15

Floor standing toilet
Table of Contents

Advertisement

4. According to different faceplates,there are different
installations of access panel as below.
4.
1) K-20341T-PNE/K-75890T-PNE Access Panel
Installation Methods:
There are four ways to install access panel:
Method one: Press from top
Method two: Remote plate installation: fix four plates
with screws
Method three: Remote installation of mask
Method four: Press from front: fix four plates with screws
1)
K-20341T-PNE/K-75890T-PNE
A. Method one: Install mask when pressing from top
a) Remove top plate, then install the rectangular
shield on the top of the tank, and tighten the screw
to fix the mask to the tank.
A.
a)
b) Cut apart the cable of the air hose and pull it out
from the mask.
b)
1288818-T01-B
Method one:
Press from top
Method three:
:
Remote installation
of mask
Suggested faceplate
installation area
R1000mm
Screw
-9-
Method two:
Remote plate installation
Suggested faceplate
installation area
R1000mm
Method four:
Press from front
Air hose
Air hose
Mask
Cable
Pinch
plate
Air hose
Pinch plate
Finished
wall
At least
80mm gap
reserved
80mm
Cover,Top

Advertisement

Table of Contents
loading

This manual is also suitable for:

Escale k-25090t-sEscale k-25089t-s

Table of Contents