absolute temperature is selected, the heating and cooling set points are adjusted to heating and
cooling temperatures.

Price Settings

When the electric rate from the utility company meets or exceeds the "ELECTRICAL RATE",
the heating and cooling set points will be adjusted according to the absolute temperature or
offset shown here. If the set point at the time of the event is more favorable (uses less energy)
than what you have programmed, the Iont System Control will use the more favorable set
point for the duration of the event. Unless otherwise indicated, all settings temperatures will be
shown in Fahrenheit degrees.

Demand Response

Demand response determines how the heating and cooling set points will be adjusted during a
demand response event with two choices - - offsets or absolute temperature. When offsets are
selected, the heating and cooling set points are adjusted by the number of degrees selected.
When absolute temperature is selected, the heating and cooling set points are adjusted to
heating and cooling temperatures.