Command Types and Responses
Response Format
4-4-3

Data Fill (DF)

Command Format
Unit
@
D
No.
00 to 31
Header DF
ASCII/HEX code
specification
A: ASCII
H: HEX
Response Format
4-4-4

Copy (CP)

44
Unit
@
W
No.
Header WT
Fill data in the specified number of bytes beginning from the specified start
address is written to the DC.
The maximum amount of data that can be written in one execution of the com-
mand is 2,048 bytes or the rest of the area from the specified start address.
×
F
Start address
A/H
Start address
No.specification
range (0000H to FFFFH)
R/W Head No. specification (1 to 4)
Unit
@
D
No.
Header
Data read from the DC memory by one R/W Head is written to the memory of
a DC within the communications range of another R/W Head. A trigger is
always written when writing to the DC.
Use the Copy command for the combination of R/W Heads 1 and 2, or R/W
Heads 3 and 4.
T
0
0
FCS
End code
00: Normal completion
Number of bytes
Specifies the number
of bytes to be written (0001H to
0800H).
If 0000 is specified, the data will be
written in the user area from the
specified start address until the final
address of the DC.
F
0
0
FCS
End code
00: Normal completion
Section 4-4
*
CR
FCS
Fill data
Fill data (2 bytes)
• Code specification H:
4-digit data
• Code specification A:
2-digit data
CR
CR