I/O Signal Wire Connections

3-2

I/O Signal Wire Connections

Used Connector Pins
3-2-1

Wiring

Note
Type
Name
Input
ID-RESET
Output
ID-RUN
ID-BUSY
ID-ERROR
General-purpose output
To connect to a Terminal Block, use an OMRON Cable preassembled with the
special connector or attach the special connector (sold separately) to a cable
yourself.
(1) Do not supply a voltage to the input terminals that exceeds the I/O cir-
cuit's specified input voltage range. Likewise, do not connect a voltage or
load that exceeds the output circuit's max. switching capacity.
(2) When the power supply terminals are marked with + and − indicators, ver-
ify that the power supply wires have not been reversed accidentally.
(3) When the equipment is subject to EC Directives (the Low Voltage Direc-
tives), a DC power supply with reinforced insulation or double insulation
must be used for the I/O power supply.
(4) Check all connector wiring thoroughly before turning ON the power sup-
ply.
(5) Do not pull on the cable. Doing so may separate the cable from the con-
nector.
(6) Do not bend the cable beyond its natural bending radius. Doing so may
damage the cable.
(7) Do not connect a 24-V DC output device to a line driver input. Doing so
may damage the internal circuits.
Pin No.
1
24 V DC
5
0 V
31
ID-RUN output
32
ID-BUSY output
33
ID-ERROR output
37
Power supply input (+V) for
the output
39 or 40
Output COM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Section 3-2
Contents
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-idsc02V600-idsc04

Table of Contents