M Group. Motor - Fagor MCS Innova Series Manual

Table of Contents

Advertisement

KV36
USER, RO
Function:
Valid values:
Default value:
KV40
USER, RO
Function:
Valid values:
Default value:
KV41
USER, RW
Function:
Valid values:

M group. Motor

MP1
BASIC, RW
Function:
c
MCSi-60/84
2
I
tMotor
Variable internally useful to the system. It measures the
internal load level of the calculation of the i
percentage used over the maximum.
0, ..., 100 %.
0 %.
IntBallastOverload
Shows the load percentage on the ballast resistor in a drive.
2
Useful for the i
t protection of the resistor. A value greater
than 100 % in this variable causes error E314.
0, ..., 100 %.
0 %.
BallastSelect
Selector that determines whether the ballast resistor is
external or internal.
0/1 external / internal (by default).
MotorType
Motor identification. The limits of certain parameters depend
on the value of MP1 (e.g. The upper limit of SP10 is 110 %
of the motor rated speed) like its default parameter
initialization through GC10.
MAXIMUM
SPEED
SIZE/POWER
MOTOR TYPE: FSA, FSP
A: LONG MOTORS
P: SHORT MOTORS
Digital Brushless AC servo drive system - Ref.0707
2
t at the motor in
See command GC10.
FEEDBACK
& FLANGE
TYPE
BRAKE/SEAL
WINDING
OPTION
VOLTAGE 220 V
SHAFT
CONNECTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

0707

Table of Contents