E
Technical data
Technical data – General
Net weight (unfilled)
Nominal capacity
Water connections
Max. water inlet temperature
Max. water inlet temperature for the post-heat-
ing
Flow temperature adjustment range
Type of installation
Safety
Max. possible draw-off points
Technical data depending on the nominal voltage
Rated power
Nominal current rating
Disconnector (circuit breaker, fuse)
Maximum impedance of the grid at 50 Hz
Technical data – Hydraulics
Maximum permissible pressure
Minimum flow rate quantity
Pressure loss for flow rate quantity
Flow rate quantity for pressure loss
Flow rate limit
Domestic hot water generation
Δϑ for provision
Technical data – Electrics
Conductor cross-section, minimum
Phases
Frequency
Degree of protection (with installed front cas-
ing)
Heating element (heating coil)
Minimum specific resistance of the water ρ15
≥ (when ϑ cold ≤ 25 °C)
Specific conductivity σ15 ≤ (when ϑ cold ≤
25 °C)
Specific resistance of the water ρ15 ≥ (when
ϑ cold > 25°C)
Specific conductivity σ15 ≤ (when ϑ cold
> 25°C)
48
VED E 11-13/1 L U
2.5 kg
0.2 l
G 3/8" A
70 ℃
55 ℃
20 ... 60 ℃
Under-counter wall
installation
Open-vented or
sealed system
Complies with national
safety regulations; does
not affect the mains sup-
ply
1
VED E 11-13/1 L U
380 V
400 V
10.1 ... 12.2 kW
11.2 ... 13.5 kW
17.8 ... 18.5 A
18.7 ... 19.5 A
16 ... 20 A
16 ... 20 A
0.28 Ω
0.26 Ω
VED E 11-13/1 L U
1 MPa
(10 bar)
> 2.5 l/min
0.06 MPa
(0.60 bar)
4 l/min
4 l/min
3.7 ... 4.5 l/min
43 K
VED E 11-13/1 L U
2.5 mm²
3/PE
50/60 Hz
IP24
Bare wire
900 Ω⋅cm
1111 µS/cm
1,100 Ω⋅cm
909 µS/cm
Installation and maintenance instructions 0020323586_00
415 V
12.1 ... 14.5 kW
19.4 ... 20.2 A
20 ... 20 A
0.28 Ω

Advertisement