G Technical Data - Vaillant aroSTOR VWL B 200/5 UK Installation And Maintenance Instructions Manual

Hide thumbs Also See for aroSTOR VWL B 200/5 UK:
Table of Contents

Advertisement

G
Technical data
Technical data – General
Nominal capacity
Outer diameter
Height
Weight (when empty)
Weight (full)
Material of the product container
Heat insulation
Maximum pressure in the drinking water circuit
Maximum inlet pressure
Pressure reducer pressure setting
Expansion valve pressure setting
Maximum pressure of the temperature and pressure re-
lief valve
Maximum temperature of the temperature and pressure
relief valve
Length of the temperature and pressure relief valve
Post-heating time in accordance with EN 12897
Permanent heat losses
Kiwa certification number
Technical data – Electrical specifications
Voltage and frequency of the product's power supply
Max amperage of the power supply circuit
Length of the electrical cable supplied
IP rating
Nominal heat output of the electric back-up heater
Heat input of the electric back-up heater
Fuse
Technical data – Connections
Connections for the domestic hot water circuit
Connecting the temperature and pressure relief valve
Air connections (inlet and outlet)
Technical data – Specifications for the heat pump
* In accordance with EN 16147:2017
Refrigerant type
Refrigerant volume for complete filling
Max. overpressure in the heat pump
Max. low pressure in the heat pump
Permitted air temperature
Sound power level LpA (V1/V2)
30
aroSTOR VWL B 200/5 UK
197.5 l
634 mm
1,458 mm
55 kg
255 kg
Stainless steel
Polyurethane foam 50 mm
0.6 MPa
(6.0 bar)
0.6 MPa
(6.0 bar)
0.3 MPa
(3.0 bar)
0.6 MPa
(6.0 bar)
0.7 MPa
(7.0 bar)
90 ℃
900 mm
06:20
1.61 kWh/24 hrs
1906704/AMD1
aroSTOR VWL B 200/5 UK
230 V – 50 Hz
8 A
1.5 m
IPX4
1,200 W
2
7 W/cm
8 A
aroSTOR VWL B 200/5 UK
3/4" outside thread, cylindrical
F 1/2"
160 mm
aroSTOR VWL B 200/5 UK
R 290
0.15 kg
2.5 MPa
(25.0 bar)
1.5 MPa
(15.0 bar)
−7 to 45 ℃
40/43 dB
Installation and maintenance instructions 0020285063_05
aroSTOR VWL B 270/5 UK
269 l
634 mm
1,783 mm
68 kg
338 kg
Stainless steel
Polyurethane foam 50 mm
0.6 MPa
(6.0 bar)
0.6 MPa
(6.0 bar)
0.3 MPa
(3.0 bar)
0.6 MPa
(6.0 bar)
0.7 MPa
(7.0 bar)
90 ℃
1,245 mm
09:28
1.77 kWh/24 hrs
1906704/AMD1
aroSTOR VWL B 270/5 UK
230 V – 50 Hz
8 A
1.5 m
IPX4
1,200 W
2
7 W/cm
8 A
aroSTOR VWL B 270/5 UK
3/4" outside thread, cylindrical
F 1/2"
160 mm
aroSTOR VWL B 270/5 UK
R 290
0.15 kg
2.5 MPa
(25.0 bar)
1.5 MPa
(15.0 bar)
−7 to 45 ℃
40/43 dB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arostor vwl b 270/5 uk

Table of Contents