  • Page 2: Table Of Contents

    Contents Contents Safety ��������������������������������������������������������������������3 Classification of action-related warnings ....3 Intended use ............3 General safety information ........3 Notes on the documentation �������������������������������5 Information storage ..........5 Scope of the instructions ........5 Appliance type............5 Product description ���������������������������������������������5 Main components ...........5 Product features .............5 Installation ������������������������������������������������������������6 Packing list .............6 Installation method ..........6...
  • Page 3: Safety 1

    The action-related warnings are classified in installation, commissioning, maintenance and accordance with the severity of the possible danger repairing of Vaillant EIWH mini VED plus/pro. It is using the following warning signs and signal words: only allowed to install Vaillant EIWHmini VED plus/pro according to the instructions.
  • Page 4 43 ℃ when using mini VED plus. Risk of appliance damage caused by unqualified domestic water Vaillant EIWH miniVED plus/pro is only used to heat domestic water. The domestic water shall comply with national domestic water quality requirement,otherwise the appliance may rust.
  • Page 5: Notes On The Documentation 2

    Notes on the documentation 2 Notes on the documentation Remark Inlet pipe temperature controller The following description is a general guide covering the Inlet temperature sensor Outlet pipe entire document. Flow sensor Outlet temperature sensor Other information must be used in conjunction with this Water resistence detection Right side panel operation and installation instructions.
  • Page 6: Installation

    4 Installation requirements, the appliance will stop. Warning� Do not install at the place directly sprayed by water! Installation Do not install outdoor! Do not install at the place where the water cannot be drained! 4�1 Packing list Do not install water heater vertically! EIWH 1 set Manual...
  • Page 7: Technical Parameters

    Installation 4 4�3 Technical parameters 4�2�4 Water route and circuit schematic diagram Product type VED E 6/1-P IN VED E 6/1-B IN Rated voltage (V) 220~/50 220~/50 Rated frequency (Hz) Rated power (kW) Electrical current (A) Temperature setting range 30~48 (℃) Rated pressure (Mpa) 0.75...
  • Page 8: Special Points Related To Installation

    5 Water heater use 4�4 Special points related to installation Water heater use Clean the pipe by water before installation to prevent 5�1 Usage of water heater residual sediment from clogging the appliance - Water heater inlet could be either upward or downward. After installation of water heater, please turn on water Water heater will not work normally if the inlet is on the mixing tap.
  • Page 9: Troubleshooting 7

    Troubleshooting 7 Troubleshooting miniVED plus series Fault phenomenon Possible reasons Troubleshooting measures 1. Excessive water flow or low 1. Adjust the water mixing tap to reduce the water flow. temperature of tap water. 2. When the water flow is too low, 2.
  • Page 10: Recycling And Disposal

    8 Recyling and disposal Recycling and disposal ▶ The competent person who installed your product is re-sponsible for the disposal of the packaging. If the product is identified with this symbol: ▶ In this case, do not dispose of the product with the household waste. ▶...
  • Page 12 Aquagreen Solutions LLP 1st Floor, Raj Palace Building, Bhandarkar Road, Lane 11, Deccan, Pune 411 004. TEL.:+91 9619506391 cs@aquagreensolutions.in © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent.