Ambient Temp. (°C)
Model
Water Temp. (°C)
Suction Pressure Peak (bar)
IM-240_NE
Evaporator Inlet Temp. (°C)
Suction Pressure Peak (bar)
IM-240_NE-21
Evaporator Inlet Temp. (°C)
Suction Pressure Peak (bar)
IM-240_NE-32
Evaporator Inlet Temp. (°C)
Note: The above data are only for reference in servicing. Actual readings may be slightly different for
each product.
Suction Pressure = Peak readings in freezing cycle
Evaporator Inlet Temp. = 5 minutes before completion of freezing cycle
Suction Pressure and Evaporator Temp.
10
21
10
15
3.0
3.5
-20
-19
3.0
3.5
-13
-11
3.0
3.5
-23
-22
43
50/60Hz
32
38
21
32
4.0
5.0
-18
-17
4.0
5.0
-10
-9
4.0
5.0
-21
-20