4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT

4.2 Status display mode

The servo status during operation is shown on the 4-digit, 7-segment LED display. Press the "UP" or
"DOWN" button to change display data as desired.
When the required data is selected, the corresponding symbol is displayed. Press the "SET" button to
display that data.
The converter unit display section can show four items of data such as the effective load factor.

4.2.1 Display examples

The following table shows the display examples.
Bus voltage
Effective load factor
Peak load factor
Regenerative load factor

4.2.2 Status display list

The following table lists the servo statuses that may be displayed.
Status Display
Bus voltage
Effective load factor
Peak load factor
Regenerative
factor
Note. Output
speed
Downloaded from
ManualsNet.com
Item
Symbol
Unit
d
V
J
%
b
%
load
L
%
torque
search engine
Status
225[V]
67[%]
95[%]
90[%]
Description
The converter unit voltage is displayed.
Continuous effective load torque is displayed. (Note)
The effective value in the past 15 seconds is displayed
relative to the rated current of 100%.
The peak output is displayed. (Note)
The peak value in the past 15 seconds is displayed
relative to the rated torque of 100%.
The
percentage
of
regenerative
permissible regenerative value is displayed.
4 - 2
Display
Indication Range
0 to 500
0 to 300
0 to 300
power
to
the
0 to 300