3 Putting into service

3.1 Putting into service with Hicom 100 E, Hicom 150 E 2.2, Hicom 150 E
Office Com and Office Point
Prerequisite
The U
U
P0/E
At least one add-on device must be connected to the reception telephone. Up to
four add-on devices may be connected, the first for hotel features, the second to
fourth mainly for room keys.
The printer is to be set to:
2400 bauds, no parity, 1 stop bit and 8 data bits.
The Hicom V.24 interface is to be set to 9600 baud.
Select 1 for CDRC port under Port assignment in the System settings menu.
Central call detail recording (CDRC) in Hicom is to be set to compressed output
format, without recording incoming calls and without call logging.
Insert the following as service codes:
*95 for System administration
*91 for Program key
*68 for Send message
#68 for Read/delete (sent) message
The first modifiable system information text, which can be sent to in-house users
be entering *68, cannot be modified if Caracas Desk is connected to the Hicom
system. You may only delete the blanks following the text so that the text is trun-
cated to the maximum length of the display text
Notes:
DTMF suffix dialling can be activated for Optiset terminals in the system under Sy-
stem settings/Automatic DTMF in order to avoid having to type in "*53" after a call for
the wake-up service.
Checksum errors 512 and 1024 are displayed the first time the system is put into ser-
vice.
A31003-E1320-S100-4-7620
Service Manual
interface to the system must be connected to the 1st or 2nd Hicom
P0/E
port (the port must be authorised for system administration).
Putting into service