Honeywell Gamewell-FCI GWF-7075 Installation And Operation Manual page 73

Addressable fire alarm control panel
Table of Contents

Advertisement

Receivers Compatible with the Control Panel
Event Description
SLC class A supervision trouble
restore
SLC programming ended, system
active
SLC programming started, system
shut down
SLC short circuit trouble
SLC short circuit trouble restore
Time changed event
Unable to report to account
trouble
Unable to report to account
trouble restore
User access code changed
User initiated manual dialer test
Walk test begin
Walk test end
Zone Events
Auxiliary power trouble
Auxiliary power trouble restore
CO Detector Alarm
CO Detector Alarm Restore
CO Detector Supervisory Alarm
CO Detector Supervisory Alarm
Restore
CO Detector Trouble
CO Detector Trouble Restore
Detector Alarm
Detector Alarm Restore
Detector trouble
Detector trouble restore
ECS Switch Trouble
ECS Switch Trouble Restore
ECS Supervisory/Tamper Alarm
ECS Supervisory/Tamper Alarm
Restore
ECS Output Group Trouble
ECS Output Group Trouble
Restore
External Reset/Silence/Fire Drill
switch trouble
External Reset/Silence/Fire Drill
switch trouble restore
LOC Mic Activated ECS Alarm
LOC Mic Activated ECS Alarm
Restore
LOC/Point ECS # Alarm
GWF-7075 Addressable Fire Alarm Control Panel Manual — P/N LS10147-002GF-E:E 06/11/2019
SIA Reporting Format
SIA pi Modifier
Module ID
SIA
Parameter Fixed Length
# (If Any)
Event
Codes
ER
Exp. ID
TE
0
TS
0
ET
Exp. ID
ER
Exp. ID
JT
0
RT
Receiver # RTNN00RRRR
YK
Receiver # YKNN00RRRR
JV
0
RX
0
TS
0
TE
0
Zone events are reported only when "Report by Zone" is selected
FT
0000
FJ
0000
GA
Zone #
GH
Zone #
GS
Zone #
GR
Zone #
GT
Zone #
GJ
Zone #
FA
Zone #
FH
Zone #
FT
Zone #
FJ
Zone #
QT
0
QJ
0
QS
0
QR
0
QT
Group #
+1000
QJ
Group #
+1000
UT
0000
UJ
0000
QA
0
QH
0
QA
Emergency
#
Table 9.2 : Reporting Formats Table (Continued)
SIA
Qualifier
Format NN - panel
ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
ERNNXX0000
3
TENN000000
3
TSNN000000
1
ETNNXX0000
1
ERNNXX0000
3
JTNN000000
1
1
3
JVNN000000
1
RXNN000000
1
TSNN000000
1
TENN000000
3
FTNN000000
1
FJNN000000
3
GANN000ZZZ
1
GHNN000ZZZ
3
GSNN000ZZZ
1
GRNN000ZZZ
3
GTNN000ZZZ
1
GJNN000ZZZ
3
FANN000ZZZ
1
FHNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
QTNN000000
1
QJNN000000
3
QSNN000000
1
QRNN000000
3
QTNN001GGG
1
QJNN001GGG
3
UTNN000000
1
UJNN000000
3
QANN000000
1
QHNN000000
3
QANN0E0000
1
Reporting
Contact ID Reporting Format
Event
Group #
Contact #
Code
331
Exp. ID
000
607
00
000
607
00
000
332
Exp. ID
000
332
Exp. ID
000
625
00
000
354
00
Receiver #
354
00
Receiver #
602
00
000
601
00
000
607
00
000
607
00
000
320
00
000
320
00
000
162
00
Zone #
162
00
Zone #
200
00
Zone #
200
00
Zone #
373
00
Zone #
373
00
Zone #
110
00
Zone #
110
00
Zone #
373
00
Zone #
373
00
Zone #
242
00
000
242
00
000
241
00
000
241
00
000
320
00
Group #
320
00
Group #
373
00
000
373
00
000
220
00
000
220
00
000
220 +
00
000
Emergen
cy #
73

Advertisement

Table of Contents
loading

Table of Contents