If the read power value exceeds 630
continued, the optical pickup may be deteriorate or damaged.
3. Press [ENTER] key on the remote controller to save the read
power value setting.
FL Display: [PLAY PWR OK] flashes 3 times, and then [REC
PWR] appears.
4. While the above FL display appears, check the "light power value".
If the value is out of the reference range, adjust with [
] keys on the remote controller.
Reference Range (light power): 5.4±0.1mW
Note
The level of the light power should not exceed 6.0mW anytime, as
this may deteriorate and damage the optical pickup.
5. Press [ENTER] key on the remote controller to save the light
power value setting.
FL Display: PLAY PWR OK flashes three times.
6. Press [MD EJECT] button on the unit to remove the laser power
meter (disc type).
7. Now the laser power adjustment is complete. Continue to the
procedure for "Laser Power Measurement".