4.7 Standards and Certifications
Declaration of Conformity – This product conforms to the following standards.
Quality
Environmental
Regional Standards
Safety
Electromagnetic compatibility
Performance
4.8 Environmental
Operating temperature range
Temperature derating
Operating altitude
Capacity derating with altitude
Inverter cooling
Transformer cooling
Humidity
Pollution degree rating
Noise
Storage temperature range
Packaging
ISO 9001
ISO 14001
Europe
CE
Australia, New
C-Tick
Zealand
IEC 62477-1
Emissions: CISPR 11 Class A Group 1
Immunity: IEC 61000-6-2
IEC 61000-4-34
0 °C to 50 °C
Above 40 °C, derate at 2% load per °C to a maximum of 50 °C
< 1000 m without derating
1% every 100 m above 1000 m
2000 m maximum
Forced ventilation
Natural convection
< 95%, non-condensing
2
< 75dBA @ 2 m
-30 °C to 50 °C
Must be kept dry at all times including transportation and
storage. Protect against contact with rain or other water or
liquids and do not store in damp or humid conditions.