Download Print this page

3M Adflo Care And Maintenance page 5

Welding protective equipment
Hide thumbs Also See for Adflo:

Advertisement

Replacement table 3M
PART
A Filter cover
B Spark arrestor
C Pre-filter
D Particle filter
E Gas filter
F Odour filter
G Adflo Battery
H Battery charger
I Breathing tube
What is listed above are basic needs. For detailed instructions and guidance, always follow the user instruction.
Adflo
Powered Air Purifying Respirator
Typically replaced
If damaged
When needed
When needed, at least
weekly.
When needed, at least
every month
According to
predetermined
employer change-out
schedule
Change when
unpleasant smell occur
When needed
If damaged
If damaged or
contaminated
Comment
To Hold and protect the filters
Replace deformed or damaged to
protect the particle filter from sparks
and spatter
Regular replacement of the prefilter
extends the life of the particle filter,
saving money while also increasing the
battery run-time
Replace when particle filter indicator
becomes red. Otherwise, replace
whenever the battery operating time
becomes too short, or when the low
airflow alarm is triggered by a fully
loaded filter.
Smell and taste is not recommended
as a measure for determining when to
change gas filters.
Odour filter is not neccessary when a
gas and vapour filter is used
Replace if the battery is no longer
taking charge to an acceptable level
Replace if any parts are damaged
Use a breathing tube cover to extend
the life time or a rubber breathing tube
for use in heavy duty environments