Sony BKNW-116 Maintenance Manual page 8

Hide thumbs Also See for BKNW-116:
Table of Contents

Advertisement

Notes when replacing the HDD
Follow the procedure (described in Section 2) when replacing the HDD.
. If an excessive mechanical shock and vibration are applied, the unpacked HDD may be damaged. Place
the unpacked HDD in a horizonal position (with the printed board side up) . Moreover, it is recom-
mended that the unpacked HDD is put on the specified HDD cushion.
. Use the specified shockless torque screwdriver when tightening and removing the screw during replac-
ing the HDD.
The HDD cushion and shockless torque screwdriver are available as a fixture.
HDD cushion :
Shockless torque screwdriver : Part No. J-6530-070-A
. HDD is easily affected by static electricity. Take measures against static electricity such as establishing
a ground, then install the HDD.
Handling of failed HDD
Handle the HDD that is removed because of a trouble or failure in the same manner as a normal HDD
following above precautions. Then pack the HDD using the specified packing materials, contact your
local Sony Sales Office/Service Center.
6 (E)
Part No. J-6530-060-A
BKNW-116