Bypass
5.
Remove the paper end sensor (bypass) (S6) [A]. (Hooks × 4)
4.16.4 BYPASS PAPER WIDTH SENSOR (S5)
1.
Remove the duplex
2.
Remove the bypass feed unit.
3.
Remove the bracket [A].
4.
Remove the bypass paper width sensor (S5) with the holder [A].
5.
Remove the bypass paper width sensor (S5) [A]. (Hooks × 4)
D0CA/D0C9/D0C8/D0CB
unit.(Duplex
Unit)
(Bypass Feed
4-182
Unit)
SM