No.
Type
SC876-02 D
Log Data Error 2
An error was detected in the handling of the log data at power on or during
machine operation.
Log encryption is enabled but encryption module is not installed.
No.
Type
SC876-03 D
Log Data Error 3
An error was detected in the handling of the log data at power on or during
machine operation.
Inconsistency of encryption key between NVRAM and HDD.
No.
Type
SC876-04 D
Log Data Error 4
An error was detected in the handling of the log data at power on or during
machine operation.
1.
No.
Type
SC876-05 D
Log Data Error 5
An error was detected in the handling of the log data at power on or during
machine operation.
SM
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Replace or set again the encryption module.
Disable the log encryption setting.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Disable the log encryption setting.
Initialize LCS memory (SP5-801-019).
Initialize the HDD (SP5-832-004).
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Log encryption key is disabled but the log data file is encrypted. (NVRAM
data corruption)
Log encryption key is enabled but the log data file is not encrypted.
(NVRAM data corruption)
Initialize the HDD (SP5-832-004).
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Only the NVRAM has been replaced with one previously used in another
machine.
Only the HDD has been replaced with one previously used in another
machine.
Attach the original NVRAM.
Attach the original HDD.
With the configuration that caused the SC, initialize the HDD
6-109
SC8xx: Overall System
D0CA/D0C9/D0C8/D0CB