Side - JVC VN-V25U VN-V26U Instructions Manual

Ip camera
Hide thumbs Also See for VN-V25U VN-V26U:
Table of Contents

Advertisement

Side

K
[MONITOR OUT] Monitor Output Selection
Switch
Use this switch to select the availability of output
from the O [MONITOR OUT] terminal as well as
the signal system.
NTSC : Outputs NTSC signals.
OFF
: No output. Select this value when
distributing images to the network.
PAL
: Outputs PAL signals.
[Default setting: OFF]
Caution:
● Images are not distributed to the network
when ANTSCB or APALB is selected.
● When the switch is changed, press the L
Reset button to reboot the unit.
L
[RESET] Reset Button
This is a button for rebooting the camera. Press
this button and release within 5 seconds to
reboot the camera.
It takes about one minute for the camera to
reboot. During startup, the [RESET] button is
disabled.
Note:
Pressing the [RESET] button for 5 seconds or
longer switches the camera to the service
verification mode. Do not press the button for 5
seconds or longer.
M
[IRIS] Iris Terminal
Use this terminal to connect the DC iris lens.
(Connection with the video iris lens is not
possible.)
(A Page 16)
N
[STATUS] Status Indicator
This status of this product is indicated in green
or orange color.
Starting up: Lights up in orange
Startup complete: Lights up in green
Error: Blinks in orange
K
L
MONITOR OUT
PAL
OFF NTSC
RESET
STATUS
IRIS
N
M
Note:
You can adjust the [LED State] settings via the
network to turn off the indicator after startup is
complete. (A Page 71)