Download Print this page
JVC VN-V225VPU Installation
JVC VN-V225VPU Installation

JVC VN-V225VPU Installation

Fixed ip dome camera
Hide thumbs Also See for VN-V225VPU:

Advertisement

FIXED IP DOME CAMERA (Vandal Resistant)
FIXED MEGAPIXEL IP DOME CAMERA (Vandal Resistant)
VN-V225VPU
READ ME FIRST
VN-X235VPU
VN-X235VPU is a high definition surveillance camera that uses high resolution CCD sensors with 4 times
the pixel count of VN-V225VPU.
Thank you for purchasing this JVC product.
Before operating this unit, please read the instructions carefully to ensure the best possible performance.
This manual contains the basic instructions for using this unit.
Please refer to [INSTRUCTIONS (Setting)] (pdf) and [INSTRUCTIONS (Installation)] (pdf) in the CD-ROM
supplied with this product for description on the detailed usage of this unit.
For the latest information, please refer to the README file in the CD-ROM supplied with this product.
● The supplied CD-ROM includes [INSTRUCTIONS (Setting)] (pdf), [INSTRUCTIONS (Installation)]
(pdf), [API Guide] (pdf), [VSIP Guide] (pdf) and [Search tool], [White Spot Correction Tool].
How to read this READ ME FIRST
● JVC holds the copyright to this manual. Any part or all of this manual may not be reproduced without prior consent
from the company.
● Windows is a registered trademark of Microsoft Corporation in the U.S.
● Product names of other companies described in this manual are trademarks or registered trademarks of the
respective companies. Symbols such as
,
and
are omitted in this manual.
● Design, specifications and other contents described in this manual are subject to change for improvements without
prior notice.
The latest version
Please visit V.NETWORKS web site to check the latest firmware at
http://www.jvc-victor.co.jp/english/products-e.html
(The latest firmware can be found on V.NETWORKS B download page)
Installation
Mounting the Camera
Setting Up the Camera
1
Remove the dome cover with the wrench provided (Screws x3)
2
Grab the inner dome and remove it from the catches (x3)
Wrench (provided)
Dome
Fall
cover
prevention
Catches
(x3)
wire
(not
Camera
removable)
Mounting the Camera
Mount the camera to the ceiling or wall.
To mount on a wall, perform the same procedures below but replace the word "ceiling" with "wall".
1
Use the provided template to make a R30 mm (1-1/8 inch) hole in the ceiling.
2
Mount the fall prevention wire that connects the camera to the ceiling.
T Fall prevention wire is not provided. Prepare a wire with due consideration of the length, strength,
pull factor and material (insulative).
A
Unscrew the mounting screw for the fall prevention wire beneath the camera and mount
the fall prevention wire.
B
Mount the fall prevention wire to a strong location.
3
Mount the camera to the ceiling
Pull out the cables from the ceiling and the cables from the camera towards the lens as shown, face
the (D) mark in the shooting direction, then mount the camera to the ceiling. To mount on a wall,
mount the camera such that the (D) mark is facing upwards.
T Screws for mounting the camera are not provided. Use the appropriate type of screws according
to the material of the location for mounting.
Fall prevention wire
R30 mm (1-1/8 inch)
1
Fall prevention wire (not provided)
2
Base
8 mm
6 mm and below
Shooting
2 mm
direction mark
R12 mm and below
R4.1_6.5 mm
3
R4 mm screw ×2 (not provided)
Note
● To mount the camera using electrical box or piping, please refer to (A [INSTRUCTIONS
(Installation)]) in the bundled CD-ROM.
Cable Connection
For safety reasons, turn on the power only after all the connections are completed.
When power is supplied to the camera, the [STATUS] indicator lights up. The indicator lights up in orange during
startup and turns green when startup is complete.
1
Connect the alarm cable
Connect the alarm cable to an external device, such as a sensor or buzzer.
Alarm cable to use (Recommended shield cable)
LST0849-001B
● Length of 50 m or shorter
● UL1007, UL1015 or equivalent products
● AWG#22 to AWG#18 or equivalent products
2
Connect to audio cable
(Recommended shield cable)
3
Connect the LAN cable
T To use the PoE power supply, connect to a PoE-compatible device and supply the power from the
LAN cable.
Note
● When using a heater unit (sold separately: KA-ZH215U), PoE power supply does not work
for the heater unit (KA-ZH215U). Be sure to use an AC 24 V power supply.
● Connecting to HUB
: Use a straight cable
● Connecting to a computer
: Use a cross cable
LAN cable to use
● STP (Recommended shield cable)
● Length of 100 m or shorter
● Category 5 and above
4
Connect the power cable
Power can be supplied to this unit either by connecting to an AC 24 V power supply or using
3
PoE. (To use PoE A [
Connect the LAN cable])
Note
● The power supply cable includes cable of the same color as the alarm cable. Check properly before
connecting.
● Make sure that power is supplied using only one of the above methods at any one time. Connecting
simultaneously using the power cable and to PoE via a LAN cable may cause the camera to break
down or malfunction.
● By default the IP addresses of all the cameras are set to 192.168.0.2. If the power of multiple
cameras within the same LAN environment are turned on at the same time, the IP addresses of the
cameras overlap, thus preventing proper access. As such, make sure to turn on the power of the
cameras one by one and set the IP addresses such that there is no overlapping.
Type of cable
Type
Color
Alarm cable
Black
Red
(shielded cable)
Brown
Orange
Yellow
Inner dome
Black
Audio cable
Brown
White
(shielded cable)
Yellow
Black
White
(shielded cable)
Yellow
Power cable
Red (unshielded cable)
Black (unshielded cable)
Power cable Connection distance when using 2-core VVF cable (Reference values)
R1.0 and above
Conductor diameter (mm)
Maximum connection distance (m)
130
Maximum connection distance (m) with
40
Heater (KA-ZH215U
Caution
The rated power of this product is AC 24 V, 50 Hz/60 Hz. Make sure to use it with the correct
voltage.
Be sure to use an AC 24 V supply that is insulated from the primary power source.
Supplying a power beyond the rated value may result in failures, smoke or fire. If the camera
breaks down, turn off the power and contact our service center immediately.
When a power beyond the rated value is supplied, the internal components may be
damaged even if no abnormality is found on the appearance and operation of the camera.
Please send to your nearest JVC dealer immediately for servicing (charged separately).
5
Wind the waterproof tape
Note
● For cables that are not used, be sure to wrap the ends individually with insulating tape.
Space for heater
Memo
● When mounting the heater unit (sold
3
10BASE-T/100BASE-TX(PoE)
terminal
LAN cable
LAN cable stopper (x2)
Processes after connection
Fill up the piping hole and mounting hole with sealant and insert the silica gel.
1
Use sealant (GE silicon) to fill up the mounting holes (x2) to which
the piping hole and screws are mounted
Note
● Make sure the holes are completely sealed up. Water or moisture may seep in and fog up the
lens and dome cover.
2
Insert the silica gel (provided)
Note
● Please make sure that rain does not seep into this unit when mounting on rainy days.
● Be sure to use the silica gel (provided). Failure to do so may fog up the camera lens and dome cover.
● If field angle is not adjusted immediately after mounting the camera, insert the silica gel (provided) after
adjustment. The silica gel (provided) will lose its effectiveness if it is exposed to the air for a long time.
1
Sealant
(GE silicon)
T This illustration is for the
purpose of explanation, and
does not represent the
actual camera.
Signal Name
Alarm input 1
Alarm input 2
Adjusting Images
Alarm output 1
When the camera is mounted, adjust the image settings while looking at the actual image.
Before touching the body of the camera, make sure to touch the metal surface of the [MONITOR] terminal to
Alarm output 2
discharge the static electricity from your body. The static electricity may cause the camera to malfunction.
GND
MIKE IN
1
Connect the [MONITOR] terminal to the test monitor
GND
LINE OUT
2
Set the [MONITOR OUT] selector switch to N or P , turn on the
GND
power or press and hold the [RESET] button for less than 2 seconds
AC 24 V Power Supply
● The camera reboots. (approximately 1 minute)
● During the restart, the [STATUS] indicator lights up in orange.
● Set to N when connecting to a NTSC monitor or set to P when connecting to a PAL monitor.
3
R1.6 and above
R2.0 and above
Adjust the shooting direction of the camera
340
540
Adjust the camera for pan, tilt and rotation, and face the camera towards the subject.
120
180
2 , 6
[MONITOR OUT] selector switch
[MONITOR] terminal
[STATUS] indicator
[RESET] button
Test monitor
1
75 K
terminated
Tilt fastening screw
separately: KA-ZH215U), please refer to
Memo
the KA-ZH215U [INSTRUCTIONS].
● Rotate both pan and rotation ±175 from the positions aligned with the camera's shooting
direction mark, pan center mark and rotation center mark. Be sure to hold the rotation control
and adjust the rotation without holding the lens section.
1,2,4
● After adjusting the field angle, tighten and secure the tilt fastening screw so that the field angle
5
will not be misaligned.
Wind the
Solder welding
Note
waterproof
or crimping
● Moving the camera when it has exceeded the adjustment range may cause its performance to
tape
deteriorate.
● As the tilt and rotation range of this unit is wide, part of this unit may be reflected in the shooting
Wind the
screen depending on the field angle and direction.
insulation tape
● Do not hold the lens section when adjusting the camera direction. The lens section may be
damaged if you apply force to it.
4
Adjust the image size
Loosen the fastening screw of the zoom adjustment ring, move the ring to the left and right to
adjust the image size. After adjusting, fasten the screw with pressing it slightly toward the lens
direction (toward the shooting direction).
5
Roughly adjust the focus
A
Lift the focus adjust gear knob, and place the catch into B in the diagram
● The gear is disengaged.
Note
● If the gear is moved outwards from B, the shaft of the gear may shift. For details on how
to return the gear to the original position, refer to ( A [INSTRUCTIONS (Installation)]) in
the supplied CD-ROM.
B
Loosen the fastening screw of the focus adjustment ring, move it to the left and
right to adjust the focus.
6
Fine adjust the focus
A
Press the [RESET] button for more than 2 seconds but less than 5 seconds.
● The camera enters the focus adjust mode and the [STATUS] indicator blinks in green
and orange alternately.
● The image is sharpened with the opening of the lens iris.
● The center of the image is enlarged. (VN-X235VPU only)
● After adjusting the focus, press the [RESET] button for more than 2 seconds but less
than 5 seconds to release the focus adjust mode.
B
Shoot the subject
2
C
Fine adjust the focus
● Return the catch to A in the diagram, and then rotate the knob to adjust the focus to the
optimum position.
D
Rotate the focus adjust gear knob about one base pitch in the direction of the arrow
in the diagram.
● This is to correct the focus shift when mounting the dome cover.
E
Hold the dome cover over the lens and check the focus
7
Hold and press the focus adjust gear between your fingers in the
direction of the arrows in the diagram, and tighten the fastening
Space for inserting
the silica gel
screw of the focus adjustment ring
8
Set the [MONITOR OUT] selector switch to OFF , then press the
[RESET] button shortly (less than 2 seconds)
● The camera restarts, and the focus assist mode is released.
Knob
Zoom adjustment ring
Catch
B
A
5
Silica gel (Provided)
Lug plate
Focus adjust gear
Knob
6
One base pitch
3
Pan: ±175
Mounting the Dome Cover
1
Mount the inner dome to the catches (x3)
2
Rotation: ±175
Tilt: ±70
Mount the dome cover
A
Remove and clean any dust or dirt on the dome cover.
Shooting direction
B
Align the base with the position alignment marks (x3) on the dome cover and mount
mark
the dome cover.
Pan center mark
C
Tighten and secure the dome cover fastening screws (x3).
Rotation center
mark
Rotation control (x4)
Inner dome
Note
● Check that the silica gel
(Provided)
● Ensure that the dome cover is secured. Insecure mounting may increase humidity, fog up the
camera or the cover may drop.
● When the cover is removed again after mounting the dome cover, check the field angle and re-
adjust the focus and field angle if necessary.
● Make sure that the fall prevention wire of the dome cover is not caught between the dome cover
and the base. Otherwise, the anti-dust and waterproof function may not work properly.
K
Continued
Focus adjustment ring
B Catch
A
7
Position alignment mark (x3)
Base
Catches
(x3)
B
C
Dome
cover
Wrench (provided)
has been inserted before mounting the dome cover.

Advertisement

loading

Summary of Contents for JVC VN-V225VPU

  • Page 1 ● Connecting to a computer : Use a cross cable ● JVC holds the copyright to this manual. Any part or all of this manual may not be reproduced without prior consent Hold the dome cover over the lens and check the focus from the company.
  • Page 2 ● To use MPEG4 images on the built-in viewer, install the open source codec “ffdshow”. You can download selected. ● Selecting [Tool]-[Pop-up Blocker]-[Turn Off Pop-up Blocker] permits all sites. “ffdshow” from the Internet. JVC is not responsible for any damages resulting from your use of open Windows Vista: source software.

This manual is also suitable for:

Vn-x235vpu