Using the Reheat Function

Using the Reheat Function
This feature allows the thermostat to turn on Electric Heating (W2)
during Cool to Dehumidify to maintain room temperature until the
dehumidification setpoint is reached. The cooling cycle will allow for
the dehumidification of the air to occur while the Electric Heating will
allow for a constant room temperature. If Reheat is enabled the Aux
icon will appear on the display during Cool to Dehumidify operation.
Press the MODE button. While holding
MODE
the MODE, press the PROGRAM
button to enter Setup screens.
PROGRAM
Press the MODE button repeatedly
10
MODE
until this setup screen appears.
Step 12 appears only if step 10 is set to "ON" and if the
Dehumidification setpoint is not 99% (see page 10.3).
On
If Reheat operation is
desired during the
dehumidification process
select On; otherwise select
Off.
Off
Press the PROGRAM button to leave the Setup screens. If no buttons are
pressed, the display will leave the setup screens after 30 seconds.
Dehumidification Notes: Reheat is only available if Cool to
Dehumidify has been set to ON in step #10 (see page 10.4).
Note: Press the
button momentarily
to move through the
setup screens. Press
and hold the
button to move back-
wards through the
setup screens.
I2
Setup
DeHumidify
OFF
H
EAT
Page 10.5
Carrier