Cleanup
12. Open Power flush attachment valve.
13. Circulate water through sprayer, into
waste pail, for 20 seconds.
14. Press ON/OFF switch to power OFF.
Power button is not illuminated when
OFF.
NOTE: Step 15 is for returning paint in hose to
paint pail. One 50 ft (15 m) hose holds approx-
imately 1 quart (1 liter) of paint.
15. To recover paint in hose:
a.
Hold gun firmly.
b.
Point gun into paint pail.
c.
Disengage trigger lock.
d.
Pull and hold gun trigger.
e.
Place Prime/Spray valve in SPRAY
position.
Press ON/OFF switch to power ON.
f.
Power button is illuminated when ON.
g.
Continue to hold gun trigger until you
see paint diluted with flushing fluid
starting to come out of gun.
28
16. While continuing to trigger gun, quickly
move gun to redirect spray into waste pail.
Continue triggering gun into waste pail
until flushing fluid dispensed from gun is
relatively clear.
ti27160a
17. Turn Pressure Control Knob to the
Prime/Clean setting.
18. Stop triggering gun. Engage the trigger
lock.
19. Place Prime/Spray valve in PRIME posi-
tion.
20. Press ON/OFF switch to power OFF. But-
ton is not illuminated when OFF.
21. On sprayers with a filter, see Cleaning
InstaClean
22. Fill unit with Pump Armor
See Storage, page 32.
23. Remove battery.
Fluid Filter, page 31.
storage fluid.
3A8429B