Cleanup - Graco GX21 Operation, Parts

Cordless electric airless sprayers
Hide thumbs Also See for GX21:
Table of Contents

Advertisement

Cleanup

Cleaning the sprayer after each use results in
a trouble free start up the next time the
sprayer is used.
For long term storage refer to Storage,
page 32.
See Cleaning Fluid Compatibility,
page 33 and Quick Reference, page
34.
To avoid serious injury from fire and explosion
when using oil-based or flammable materials:
Do not spray solvents through the spray
tip. Always remove tip guard and spray tip
before flushing. Clean tip guard and spray
tip in a bucket of compatible solvent.
Clean in a well-ventilated area. Keep a
good supply of fresh air moving through
the area.
When flushing with solvents, always
ground the sprayer and waste container.
Cleaning From a Pail (Stand Models)
Pail flushing only works with models that
have a suction tube.
1.
When using oil-based or flammable
material, follow Grounding
Instructions, page 10.
2.
Perform Pressure Relief Procedure,
page 14.
3.
Remove tip guard and spray tip. For
additional information, see Clean the
Gun, page 31
3A8429B
4.
Remove suction tube and drain tube
from paint, wipe excess paint off out-
side.
5.
Separate drain tube (smaller) from suc-
tion tube (larger).
6.
Place empty waste and flushing fluid
pails side by side.
7.
Place suction tube in flushing fluid. See
Cleaning Fluid Compatibility, page
33, for appropriate flushing fluid to use.
Place drain tube in waste pail.
Cleanup
ti27495a
25