Hunter 44905 Owner's Manual page 49

7 day programmable thermostat
Hide thumbs Also See for 44905:
Table of Contents

Advertisement

Refresh Fan
If the fan switch on the bottom of the thermostat is set to Refresh then for every hour
that your system does not run, your system's fan will come on and run for 15 minutes
to circulate the air in the house, then shut down.
Cool Runtime
When your system is running in cool mode, and the compressor shuts down, your fan
will continue to run for 15 seconds to force the remaining cold air in your ducts out.
(This option cannot be changed or disabled.)
Stage Timer
If you have a multi-stage heat pump, the stage timer works in conjunction with your
second stage span to determine when your second stage heat will turn on. If your
primary heat runs for 30 minutes without reaching the set temperature or activating
second stage heat, the stage timer will activate your second stage heat. (This option
cannot be changed or disabled.)