3.9

Connection with Maxsea TZ Professional

Maxsea TZ Professional can display the sonar picture of this equipment and control
some basic operation (range, tilt, gain control) of the sonar from the PC. To display the
sonar picture in TZ Professional, connect the PC that TZ Professional is installed to
the processor unit, via the LAN interface.
Check the following points to sonar data to the TZ Professional:
• The PC that TZ Professional is installed is connected to the LAN1 port of the pro-
cessor unit.
Note: Use the switching HUB (HUB-100) to connect between the processor unit
and the PC.
• The standby popup appears on the sonar screen of the TZ Professional while the
transducer is standby (transducer is retracted).
• The transmission start popup appears on the sonar screen of the TZ Professional
while the transducer is transmitting (transducer is projected).
Note 1: When the [TX] is set to [OFF] in the [Test] menu, the sonar picture is not
displayed in the TZ Processional screen even if the transducer is projected.
Note 2: When the ship is docked, you cannot transmit the transducer. Therefore,
perform the dummy test from the [Test] menu and check the dummy test picture is
displayed on the sonar screen of the TZ Professional.
For details about TZ Professional, see the operator's manual of TZ Professional.