OPERATING INSTRUCTIONS

Read the ENTIRE IMPORTANT
SAFETY INFORMATION
section at the beginning of this
manual including all text under
subheadings therein before set
up or use of this product.
Inspect tool before use, looking
for damaged, loose, and
missing parts. If any problems
are found, do not use tool until
repaired.
Work Piece and Work Area Set Up
1.
Designate a work area that is clean
and well-lit. The work area must not
allow access by children or pets to
prevent distraction and injury.
2.
Route the air hose along a safe
path to reach the work area without
creating a tripping hazard or exposing
the air hose to possible damage.
The air hose must be long enough
to reach the work area with enough
extra length to allow free movement
while working.
3.
There must not be hazardous objects
(such as utility lines or foreign
objects) nearby that will present a
hazard while working.
Full Sequential Safety Trip
Mechanism Definition
This tool has a full sequential safety
trip mechanism, which is designed to
prevent inadvertent firing. The tool should
only fire if the Safety Nosepiece is pressed
against the workpiece prior to pulling the
Trigger. It should only fire again if both
Trigger and Safety Nosepiece are released
SKU 92359
For technical questions, please call 1-800-444-3353.
first. The Tool should not fire if the Safety
Nosepiece is not pressed against the
workpiece.
Full Sequential Safety Trip
Mechanism Testing Procedure
FROM ACCIDENTAL
OPERATION:
Empty the tool before this
procedure. Point the tool at a
piece of scrap wood when
testing.
1.
Disconnect the tool from the air
supply.
2.
Empty the Nail Canister (82) of
fasteners.
3.
Check that the Trigger (47) and
the Safety Nosepiece move freely,
without sticking.
4.
Connect the air supply to the tool and
set within the Operating Air Pressure
indicated on the Specification chart.
5.
Test the tool by pressing the Safety
Nosepiece against the workpiece
without pulling the Trigger. The Tool
must not cycle (fire). If it cycles
(fires), stop immediately and have
it repaired by a qualified service
technician.
6.
Hold the tool away or off of the
workpiece. The Safety Nosepiece
should return to its original position.
Squeeze the Trigger. The tool must
not cycle (fire). If the tool fires, stop
immediately and have it repaired by a
qualified service technician.
TO PREVENT
SERIOUS INJURY