Functional Description; Specifications; Initial Tool Set Up/ Assembly; Air Supply - Central Pneumatic CONTRACTOR 92359 Set Up And Operating Instructions Manual

Coil roofing nailer kit contractor series
Hide thumbs Also See for CONTRACTOR 92359:
Table of Contents

Advertisement

FUNCTIONAL DESCRIPTION

Specifications

Operating Air
65-90 PSI Maximum
Pressure
Air Inlet
1/4" -18 NPT
Fastener
.120" Dia. Shank, 3/4" to 1-3/4" L,
Capacity
(120 capacity)
Air
2 SCFM @ 90 PSI
Consumption
7 SCFM (For Continuous Use)
Safety
Full Sequential Safety
Carrying Case
Air Tool Oil
Accessories
Hex Wrenches (3mm, 4mm, 5mm)
ANSI-Approved Safety Goggles
Nail Coil (7/8" Nails)
Safety Nosepiece - Also called the
workpiece contact, the Safety
Nosepiece helps prevent the tool
from firing unless it is pressed against
an object.
INITIAL TOOL SET UP/
ASSEMBLY
Read the ENTIRE IMPORTANT
SAFETY INFORMATION
section at the beginning of this
manual including all text under
subheadings therein before set
up or use of this product.
Note: For additional information regarding
the parts listed in the following pages,
refer to the Assembly Diagram near
the end of this manual.
Unpacking
When unpacking, make sure that the
item is intact and undamaged. If any parts
are missing or broken, please call Harbor
Freight Tools at 1-800-444-3353 as soon
as possible.
SKU 92359
For technical questions, please call 1-800-444-3353.
• This air tool may be shipped with a
protective plug covering the air inlet.
Remove this plug before set up.

Air Supply

Use only clean, dry, regulated,
compressed air to power this
tool. Do not use oxygen,
carbon dioxide, combustible
gases, or any other bottled
gas as a power source for this
tool.
Coupler
Plug
Tool
Quick
Coupler
Valve
Oiler
Quick
Coupler
Regulator with
Pressure Gauge
Recommended Air Line Components
1.
Incorporate a filter, regulator with
pressure gauge, oiler, in-line shutoff
valve, and quick coupler for best
service, as shown in the diagram
above. An in-line shutoff ball
valve is an important safety device
because it controls the air supply
even if the air hose is ruptured.
The shutoff valve should be a ball
valve because it can be closed
quickly.
TO PREVENT
EXPLOSION:
Coupler
Plug
Air Hose
on Reel
Filter
Air
Compressor
REV 09e
Page 8

Hide quick links:

Advertisement

Table of Contents
loading