Pump Housing Assembly P/N 133373 - Graco EGP 25T817 Instruction Manual

115 vac egp on-demand pump
Table of Contents

Advertisement

2. Push the pressure switch wire into the wire clamp
and into the terminal box through the strain relief
(F
. 12 and F
. 13).
IG
IG
3. Twist the strain relief nut on using a wrench until
tightened (F
. 13).
IG
4. Crimp the fork connector to one of the pressure
switch wires (F
. 13).
IG
5. Connect the crimped wire to E1.
6. Reinsert the second wire back into the connector
containing the yellow and white cables (F
7. Place the gasket onto the terminal box.
E1
Strain Relief
F
. 13
IG
8. Replace the terminal box cover.
9. Insert the four terminal box cover screws and
tighten (F
. 14).
IG
3A8570B
. 13).
IG
Strain Relief Nut
terminal Box
Cover Screws
F
. 14
IG
10. Complete using the Installation information
beginning on page 9.
Pump Housing Assembly P/N
133373
Disassembly
1. Follow Pressure Relief Procedure. page 10.
2. Turn off and disconnect the power to the pump.
3. Remove the pump from the tank.
4. Remove the suction tube from the pump.
5. Remove the four terminal box cover screws (F
15).
Repair
.
IG
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

25t817

Table of Contents