Advertisement

2.0 – INSTALLATION
2.1 INSERTING MIG GUN INTO A WIRE FEEDER
For most power pins
1. Insert power pin to shoulder and secure.
2. Insert control plug to control housing of MIG
gun.
3. Insert control plug into feeder.
4. Feed welding wire into power pin by hand and
tighten drive rolls.
NOTE: On Lincoln® feeders it is necessary to connect the gas hose to the barbed fitting on the power pin.

2.2 INSTALLING QUICK CONNECT BLOCK TO FEEDER

STEP #1
Insert the correct feeder adaptor liner for desired wire
diameter (2 provided) flush with the threaded end of
the feeder adaptor.
Tighten set screw.
Thread feeder adaptor into Quick Connect Block and
tighten.
STEP #2
Position assembly into feeder adaptor and trim liner within 1/16" (1.6 mm)
of the drive rolls and remove burrs if necessary.
Secure assembly into feeder.
Connect gas hose to gas fitting on feeder.
Connect power cable to 1/2" (13 mm) power bolt with appropriate lug.
Tighten all connections.
Feed welding wire through assembly by hand and tighten drive rolls.
QUICK CONNECT
BLOCK
14
SET SCREW
FEEDER ADAPTOR
FEEDER ADAPTOR LINER
DRIVE
ROLLS