Prodigy Eclipseä 600, 800, 1000
Service Diagnosis
Problem or Symptom
No ice
* Additional diagnostics for this component are on the following pages
Possible Cause
No power to ice making section
No power to condensing unit
No lights on controller
Unit manually switched off
Power to both sections, controller reset,
but condensing unit does not operate
No power to compressor contactor coil.
No water to ice making section, controller
blinking water light
Ice making section has exceeded
maximum freeze time and controller has
shut down the system
Ice making section has exceeded
maximum harvest time and shut down the
system
CP solenoids do not activate during
harvest
Bin full code displayed but bin is not full
February 2008
Page 44
Probable Correction
Restore power
Restore power
Check transformer
Push and release the On button, ask user
why it was shut off
Interconnecting control wire
disconnected, reconnect it
Low or high pressure cut outs open,
check system pressures
Check toggle switch in CP.
Check EH222 compressor relay.
Restore water supply, check water filters,
reset controller
Check inlet water valve operation
Check water level sensor
Condenser coils may need cleaning
Check condenser fan blade and motor
Check for excessive air intake
temperatures at condenser coil
Check compressor contactor
Check compressor and starting
components
Check water pump
Check purge valve for leak through
Check vapor inlet valve for leak though
Check ice making section for lime scale
build up, clean as needed
Check condenser by pass valve
Check vapor inlet valve*
Check headmaster
Check curtain switch
Check inlet water valve for leak through
Check for obstruction in ice delivery chute
Check solenoid relay in EH222
Check curtain switch
Check optional thermostat*