Download Print this page

Scotsman Prodigy Eclipse 600 Manual page 17

Advertisement

Condensing Section Assembly: ER2C6810
(C600/800/1410CP to ER2C6810):
1. Remove cartons from compressor package and
two-circuit condenser.
2. Remove top from both units.
3. Remove front panel from CP unit.
4. If installing one CP unit, locate legs, secured to
ERC unit. If installing two CPs, skip steps 5, 6, 7
and 9.
5. Locate fasteners inside junction box of ERC
unit.
Locate
Fastener
Package
6. Assemble rear legs to ERC using fasteners from
prior step.
7. Locate wire package in CP unit. Remove short
wires and two wire nuts.
8. Use wire & wire nuts from step 7 to connect to
the wires inside the junction box of the condenser.
Return junction box cover to its original position.
9. Place front (with junction box) of ERC on back
flange of CP unit.
10. Secure CP unit to ERC.
11. Attach leg brace between ERC unit and CP
unit.
12. Pull ERC female refrigerant connections
forward to engage male connections on CP unit.
13. Rotate swivel nuts to tighten refrigerant
connections. Use a back up wrench to hold female
connection to prevent tearing of the diaphragms.
Prodigy Eclipseä 600, 800, 1000
14. Route wires from ERC junction box to CP
junction box.
15. Attach condenser wires (from wire package) to
L1 and L2 of the contactor.
Connect
Power
Here
Connect
Fan Motor
Leads
Two Circuit Condenser Installation, CP Unit
Contactor, Three Phase Shown
The fan motor of the two circuit condenser will
always be on.
If installing two CP units, connect the fan motor
leads to only ONE of the two contactors.
16. Return tops to their original positions.
Rotate Swivel
Nuts to Connect
Condenser
System to
Compressor
Unit
February 2008
Page 17

Advertisement

loading

This manual is also suitable for:

Prodigy eclipse 800Prodigy eclipse 1000