Download Print this page

Frymaster H14 Series Installating And Operation Manual page 27

Electric fryers
Hide thumbs Also See for H14 Series:

Advertisement

INTERNATIONAL KESSEL SERVICE
Problem
Fryer heats until
high-limit trips
without heat
indicator ON.
Fryer stops heating
with heat indicator
ON.
6.2.2 Error Messages and Display Problems
Problem
Basket lift timer
display shows
.
Basket lift timer
display shows
.
Probable Causes
Contactor or controller has failed.
The high-limit thermostat or
contactor has failed.
Probable Causes
Open drain valve or problem with
latching circuits
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
WWW.INTERNATIONALKESSEL.COM
6-4
Corrective Action
If available, substitute a controller
known to be working for the
suspect controller. If the substitute
controller functions correctly,
order a new controller from FASC.
If substitution of the controller
does not resolve the problem, the
most likely cause is a contactor
failed in the closed position. Call
FASC.
The fact that the heat indicator is
ON indicates that the controller is
functioning properly and is calling
for heat. The high-limit thermostat
functions as a normally closed
switch. If the thermostat fails, the
"switch" opens and power to the
elements is shut off. If the
contactor fails to close, no power is
supplied to the elements.
Determining which component has
failed is beyond the scope of
operator troubleshooting. Call
FASC.
Corrective Action
Verify that the drain valve is fully
closed. The fryer will not function
if the drain valve is not fully
closed. If the drain valve is fully
closed, the problem is within the
latching circuitry and is beyond the
scope of operator trouble shooting.
Call FASC.
This in an indication of a
malfunction in the temperature
control circuitry, including a
failure of the high-limit thermostat.
Shut the fryer down immediately
and call FASC.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

H17 seriesH22 series