Disconnecting Battery Cables - Invacare Pronto M71 Owner's Operator And Maintenance Manual

Hide thumbs Also See for Pronto M71:
Table of Contents

Advertisement

DETAIL "A"
GREY Connector
RED Battery
Cable
Mounting
Screw with
Fuse
POSITIVE (+)
Battery
Terminal
DETAIL "B"
NEGATIVE (-) Battery
POSITIVE (+)
Terminal Cap
Battery
Terminal Cap
NOTE: Handles on batteries removed for clarity.
FIGURE 15.3 Connecting/Disconnecting Battery Cables

Disconnecting Battery Cables

The use of rubber gloves is recommended when working with batteries.
NEVER allow any of your tools and/or battery cables to contact BOTH battery ter-
minals at the same time. An electrical short may occur and serious personal injury
or damage may occur.
Part No 1143240
NOTE: Handles on batteries
removed for clarity.
Mounting Screw
U1 Battery
Locknut
Tie-wraps
U1 Battery
WARNING
Wide Part of
Strap
NEGATIVE (-)
Battery
Terminal
Locknut
BLACK
Battery
Cable
Hook and Loop Fastening Strips
GREY Connector
U1 Batteries
59
Pronto® M71™Base with SureStep®
SECTION 15—BATTERIES
Battery Lifting Strap
Handle
BLACK Connector on
M71 Standard OR RED
Connector on M71
Formula PTO Plus
Plug into
Controller