BEFORE
STARTING
YOUR
FURNACE
Examine
the furnace
installation
monthly
to determine
that:
1. All flue gas
carrying
areas
external
to the
furnace
(i.e.
chimney,
vent connector)
are clear and free of obstructions.
2. The vent
connector
is in place,
slopes
upward
and
is
physically
sound without
holes or excessive
corrosion.
3. The return-air
duct connection(s)
is physically
sound,
is
sealed to the furnace casing, and terminates
outside the space
containing
the furnace.
4. The physical
support ofthe furnace is sound without
sagging
cracks, gaps, etc. around
the base.
5. There are no obvious
signs of deterioration
of the furnace.
Ag23s0
Fig. 5 - Burner
Flame
6. The burner flames are in good adjustment.
(See Fig. 5.)
STARTING
AND SHUTTING
DOWN
YOUR
FURNACE
Instead
of a continuously
burning
pilot
flame
which
wastes
valuable
energy,
your
furnace
uses
an automatic,
hot
surface
ignition
system
to light the burners
each time the thermostat
starts
your furnace.
Follow
these important
safeguards:
Never attempt
to manually
light the burners with a
match or other source of flame.
Fig. 6 - Do Not Light
Burner
with Match
A92319
Read and follow the operating
instructions
on inside of
main furnace door, especially
the item that reads as
follows:
Wait 5 minutes
to clear out any gas. Then smell for gas,
including
near the floor. If you smell gas, STOP!
Follow "B" in the safety information
above on this
furnace
label. If you don't smell gas, go to the next
step.
If a suspected
malfunction
occurs with your gas control
system, such as the burners
do not light when they
should,
refer to the shutdown
procedures
on inside of
main furnace door, or in the "Shutting
Down Your
Furnace"
section and call your dealer as soon as
possible.
FIRE
AND
EXPLOSION
HAZARD
Failure
to follow
this warning
could
result
in personal
injury/death
or property
damage.
Should
the gas supply
fail to shut off or if overheating
occurs,
turn
off the manual
gas valve
to the furnace
BEFORE
turning
off the electrical
supply.
(See Fig. 8.)
CHECK
AIR FILTER:
Before attempting
to start
your furnace,
be sure the furnace
filter is clean and in
place. See "Performing
Routine
Maintenance"
section
in this manual.
Then proceed
as follows:
Steps For Starting
Your Furnace
1. Set your room thermostat to the lowest temperature
setting.
(See Fig. 7.)
2. Close the external
manual
gas valve. (See Fig. 8.)
o
o
\
Fig.
7 - Lowest
Temperature
Setting
A08013
A06188
Fig. 8 - (.'lose Valve
3. Turn OFF electrical
supply to the furnace.
(See Fig. 9.)
4. Remove
main furnace door. (See Fig. 10.)
5. The gas valve will have a control
switch to turn off and on.
Turn
the control
switch
on the gas control
to the OFF
position
and wait 5 minutes.
(See Fig. 11.) Then smell for
gas, including
near the floor. If you smell gas, STOP!
Follow
"B" on furnace
label. If you don't smell gas, go to next step.
6. After waiting
5 minutes,
turn the control
switch
on the gas
control to the ON position.
(See Fig. 12.)