COMBUSTION
AREA
AND VENT
SYSTEM
Visually
inspect the combustion
area and vent system
before each
heating
season.
Make
sure that all PVC
pipes leading
into the
combustion
area and vent are free from an}, cracks and sags.
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
this warning
could
result
in personal
injury or death.
If holes
are found
in the pipes
or if any portion
has
become
disconnected,
toxic fumes can escape into your
home.
DO NOT OPERATE
YOUR
FURNACE.
Call
your dealer for service.
Check the combustion-air
intake and vent pipe on the outside
of
your home
for blockage.
When dirt, soot. scale, or rust is allowed
to build up, your furnace
can
suffer
a
loss
of
efficiency
and
perform
improperly.
Accumulations
on the main burners
can result
in firing
out of
normal
sequence.
This
delayed
ignition
creates
an alarmingly
loud sound.
UNIT
OPERATION
HAZARD
Failure
to
follow
this
caution
may
result
in property
damage.
If your furnace makes
an especially
loud noise
when the
main burners
light,
shut down
your furnace
and call your
dealer.
To inspect
the combustion
area and vent system,
you will need
a flashlight.
Refer
to Fig. 3 and proceed
as follows:
A00223
Fig. 33 - Remove
Burner
Enclosure
Front
A92330
Fig. 34 - Burner
Flame
HEADING
SOUTH
FOR
THE
WINTER?
DON'T
FORGET
YOUR
FURNACE!
CARBON
MONOXIDE
POISONING
HAZARD
Failure
to follow
this warning
could
result
in personal
injury or death.
If dirt, rust, soot, or scale accumulations
are found, call
your dealer. Do not operate
your furnace.
1. Turn off the gas and electrical
supplies
to the furnace
and
remove
the main furnace door. (See Fig. 8, 9. and 10.)
2. Remove
burner enclosure
front. (See Fig. 33.)
Inspect
the gas burners,
igniter
area, and remainder
of furnace for
dirt, rust, soot, or scale.
3. Inspect
the combustion-air
and vent PVC pipes for sags,
holes,
cracks,
water
leaks,
blockage
or disconnections.
Horizontal
portions
of pipes must slope downward
toward
furnace.
4. Reinstall
burner
enclosure
front.
5. If your furnace is free of the above conditions,
replace main
furnace
door and turn on electrical
and gas supplies
to the
furnace.
(See Fig. 13, 14, and 15.)
6. Start the furnace and observe its operation.
Watch the burner
flames to see if they are clear blue. almost transparent.
(See
Fig. 34.) If you observe
a suspected
malfunction,
or the
burner flames are not clear blue, call your dealer.
UNIT AND
PROPERTY
DAMAGE
HAZARD
Failure
to follow
this caution
may result
in damage
to the
furnace
and other property
damage.
If the furnace
is installed
in an unconditioned
space where
the
ambient
temperatures
may
be 32"F
(0°C)
or lower,
freeze protection
measures
must be taken to prevent
minor
property
or product
damage.
UNIT
COMPONENT
DAMAGE
HAZARD
Failure
to follow
this caution
may result
in damage
to tire
furnace
and other property
damage.
Do not use ethylene
glycol
(Prestone
II antifreeze
coolant
or
equivalent).
Failure
of plastic components
may occur.
Since the furnace
uses a condensing
heat exchanger,
some water
will accumulate
in the unit as a result of the heat transfer
process.
Therefore.
once it has been operated,
it cannot
be turned
off and
left off for an extended
period
of time when
temperatures
will
reach
32°F
(0°C)
or lower
unless
winterized.
Follow
these
procedures
to winterize
your furnace:
1. Obtain propylene
glycol
(RV/swimming
pool antifreeze
or
equivalent).
2. Turn off electrical
supply to the furnace. (See Fig. 17.)