Step 7 - Setting Zones Types (Location 1)

There are 8 zones for each partition. We use partition 1 in this example; settings for other partitions are similar. The
pre-delivery values of the zones is shown below. It should satisfy most installations.
Zone (Sub-location)
1
2
3
4
5
6
7
8
If necessary, installers can also change the zone type. Please refer to the table on the next page for the value of
different zone types.
The input format is: [Installer Code] [*] [1] [*] [Zone Number] [*] [Zone Type] [*]...[#] [#]
Zone Type
DISABLED
PRIMARY ENTRY/EXIT ZONE
FOLLOWER ZONE
PANIC/PRIORITY ZONE
INSTANT ZONE
ARM/DISARM ZONE
SECONDARY ENTRY/EXIT ZONE
For example, if you don't need follower zone and zone 7 and 8 are not used, you can change Zone 2 (default
Follower Zone) to instant zone and disable zone 7 and 8.
Enter 1479* 1* 2* 4* 7* 0* 8* 0*
and then press # # to exit installer menu.
Explanation:
1479*
Location 1
Installer code
(Zone types)
8
Default Value
01
PRIMARY ENTRY/EXIT ZONE
02
04
04
04
04
04
04
Value
0
1
2
3
4
5
8
1*
2*
Zone 2
Zone Type
FOLLOWER ZONE
INSTANT ZONE
INSTANT ZONE
INSTANT ZONE
INSTANT ZONE
INSTANT ZONE
INSTANT ZONE
Zone Type
Instant Fire Zone(New)
FIRE ZONE
TAMPER ZONE
24 HOUR ALARM ZONE
WARNING ZONE
PUSH TO ARM ZONE
OUTDOOR INSTANT ZONE
4*
7*
Instant Zone
Zone 7
WGAP864 Alarm Panel Quick Installation Guide - Version: WGA-Q321
Value
9
10
11
12
13
14
15
0*
8*
Disable
Zone 8
0*
Disable