Step 7 - Setting Zones Types (Location 1)

There are 8 zones for each partition. We use partition 1 in this example; settings for other
partitions are similar. The pre-delivery values of the zones is shown below. It should satisfy
most installations.
If necessary, installers can also change the zone type. Please refer to the table below for the
value of different zone types.
The input format is:
DISABLED
PRIMARY ENTRY/EXIT ZONE
FOLLOWER ZONE
PANIC/PRIORITY ZONE
INSTANT ZONE
ARM/DISARM ZONE
SECONDARY ENTRY/EXIT ZONE
For example, if you don't need follower zone and zone 7 and 8 are not used, you can change
Zone 2 (default Follower Zone) to instant zone and disable zone 7 and 8.
Enter:
1479*
Installer
code
and then press # # to exit installer menu.
i.e. enter:
Copyright © Cornick Pty. Ltd. 2018
Zone
Default Value
(Sub-location)
1
2
3
4
5
6
7
8
[Installer Code] [*] [1] [*] [Zone Number] [*] [Zone Type] [*]...[#] [#]
Zone Type
1*
2*
Location
Zone 2
1
(Zone
Types)
1479* 1* 2* 4* 7* 0* 8* 0* # #
01
PRIMARY ENTRY/EXIT
02
FOLLOWER ZONE
04
INSTANT ZONE
04
INSTANT ZONE
04
INSTANT ZONE
04
INSTANT ZONE
04
INSTANT ZONE
04
INSTANT ZONE
Value
Zone Type
0
Instant Fire Zone(New)
1
FIRE ZONE
2
TAMPER ZONE
3
24 HOUR ALARM ZONE
4
WARNING ZONE
5
PUSH TO ARM ZONE
8
OUTDOOR INSTANT ZONE
4*
7*
Instant
Zone 7
zone
ZONE
0*
8*
Disable
Zone 8
Value
9
10
11
12
13
14
15
0*
Disable
Page 6