Installing Cabinets In A New System - Northern Telecom DNC-50 Installation Manual

Dynamic network control systems
Table of Contents

Advertisement

16
Installing a -48 Vdc Power Distribution System
1
1
TOOLS:
1
1
1
1
1

Installing Cabinets in a New System

IMPORTANT: When adding a cabinet to an existing system, refer to the
procedure 'Adding a Cabinet to an Existing System', later in this part, for
instructions.
Cabinets are shipped without SRUs installed. The SRUs are plugged in after
all cabinets in the system are installed.
Once the floor area has been prepared and the cabinets positioned in the
appropriate marked positions, install and interconnect them as follows:
(1)
(2)
Flat washer, #6
Hingeplate.
Flat-blade screwdriver
Carpenter's level
Hexagonal nutdriver (1/4 inches)
Allen wrench (5/64 inches)
Small wire cutter for plastic tie-wraps.
Position the first cabinet in the left-most position (as viewed from the
front) along the front-of-cabinet line made when preparing the floor
layout. You can use a jumper assembly as a straight edge when aligning
the cabinets.
Screw in all four feet on the bottom of the cabinet (fully clockwise),
then unscrew each foot by four turns. (See Fig. 4-1.) The feet are
threaded at 16 turns per inch.
Practice 450-1011-201