10. Power Transformer

z
Remove the top cover and motor cover.
x
Remove the board-A case lid and pull out the
transformer connectors (primary and secondary) from
the circuit board-A.
c
Remove the driving motor.
v
Remove the setscrew
b
Remove the setscrews
n
To attach: follow the above procedure in reverse.

11. Machine Socket

z
Remove the top cover, belt cover and motor cover.
x
Remove the board-A case lid and pull out the
machine socket connectors (primary and secondary)
from the circuit board-A.
c
Remove the setscrews
v
Remove the setscrews
b
To attach: follow the above procedure in reverse.