20. Operating Sequence

For All Installations
Preliminary Checks
Temporarily remove all access panels.
Ensure that the area around the blower motor is free of sawdust, insulation, dirt, or other small
loose debris. Such material could clog the blower motor's air ducts and reduce the air flow through
the blower motor.
Make sure the union connection at the check valve is securely hand tightened.
Check that the piping from the blower motor and the check valve to the butterfly valves is properly
connected and supported.
Ensure that cable ties or other clips support the air piping and electrical harnesses at the bath.
Ensure that any unused electrical connectors are supported above the floor.
Turn on power to the unit.
NOTE: Troubleshoot any problems as per the "Troubleshooting" section.
Confirm Blower Motor Operation
Fill the bath to a level at least 2" (5 cm) above the top of the highest airjet.
Press the power button on the user keypad.
Observe that the user keypad icons illuminate. The air flow mode icon and the chromatherapy cycle
icon (if provided) are lighted green. The Zone 1, Zone 2, and Zone 3 icons are also illuminated
green since all three zones are activated.
Observe that the blower motor starts at a midrange speed.
If provided, verify that all four chromatherapy lights are illuminated. The cycling of colors may not
be readily apparent as the cycle time may be rather long.
NOTE: The purge cycle mode cannot be selected while there is water in the bath.
Rotate the rotating ring through each of the available icon positions.
Verify that, as each icon is selected, it begins flashing. If the mode is operating, the light will flash
green. If the mode is not operating, the icon will flash blue.
Verify that, as each icon is deselected, it stops flashing.
Kohler Co.
Zone 1
Rotating Ring Key Pad
Zone 2
Zone 3