Make Power Connections - Remote - Kohler K-1110 Installation Manual

Bath with airjets
Hide thumbs Also See for K-1110:
Table of Contents

Advertisement

Available languages

Available languages

Power
Blue
Supply
Cable

14. Make Power Connections - Remote

WARNING: Risk of electric shock. To reduce the risk of electric shock, connect the control to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard. A dedicated 220-240 V, 15 A,
50/60 Hz circuit is required. The bath will only operate at 208 V through 254 V and at 50 Hz or
60 Hz.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
NOTE: The bath with airjets model number is printed on a label near the bath blower motor. This label
also identifies the electrical rating of the bath.
Ensure that the control power supply cord is properly routed to the control power junction box. The
control power supply cord a contains a brown wire (Line 1), a blue wire (Line 2), and a green wire
with a yellow stripe (ground or earth).
Install a strain relief (not provided) for the power supply cable to the control power junction box.
Route the power supply cable to the control power junction box.
As required strip the jacket and wire insulation on both cables in order to make the connections.
For installations in the United States, mark any white conductor in the supply power wiring with
red or black tape as required by the NEC.
Connect service to the control power junction box.
Provide a separate equipment earthing or grounding conductor to the spare earth/ground lug
located on the junction box. This conductor must not be connected to any current-carrying
conductor. Follow local electrical codes.
Bond in accordance with national and local codes.
Clean the area of all dust and debris.
All wiring harnesses have been prewired at the factory. Ensure that all wires are securely fastened.
NOTE: Your wiring harness includes an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
1035472-2-G
Bond in accordance with
national and local codes.
Ground (Green with Yellow Stripe)
Wire Connectors
Strip back the jackets
From Control
about 3" (7.6 cm) of the
power cable and control
motor power supply.
60 Hz
50 Hz
L1
L1
Brown
L2
N
Control
New Field Cable
To Blower Motor
Power
Supply
Cable
From Control
Brown
Blue
22
Control Power
Junction Box
Control
Power
Supply
Blower
Motor Cord
Provide power supply
to the control.
Kohler Co.