Installation

Rear Panel

A note on I/O boards

See figure 2-2. Each I/O board is identified by the input and
output numbers supported by the board position (1 - 8, 9 - 16,
and so on) The transceiver modules on fiber optic I/O boards
and the BNC connectors on SDI/HD-SDI boards are identified
as A through H.
Input 1
Input 2
Output 1
Output 2
OUT
IN
OUT
IN
A
B
RESET
IN
IN
OUT
OUT
A
B
Output 9
Output 10
Input 9
Input 10
A
B
C
D
MUTI-RATE SDI INPUTS
IN
IN
OUT
OUT
Input 26
Input 28
Input 25
Input 27
Input 29
Figure 2-2 — Arrangement of inputs and outputs on
the I/O boards
Locations A through H correspond to the input and output
numbers identified by the board position numbers. (For
example, the input and output numbers supported by the
I/O board in location 9 - 16 are as follows: A = 9, B = 10, C = 11,
D = 12, E = 13, F = 14, G = 15, and H = 16.)
On the fiber optic I/O boards, locations A through H correspond
to the transceiver modules, each of which includes an input and
an output. Therefore, locations A through H are numbered from
left to right.
On the SDI/HD-SDI I/O boards, inputs and outputs are
grouped separately, with inputs A through H on the left and
outputs A through H on the right.
2-2
Fiber Matrix 6400 Switcher • Installation
Refer also to the Fiber Matrix 6400 Switcher User's Manual at www.extron.com.
Input 3
Input 4
Output 3
Output 4
Slot 1
OUT
IN
OUT
IN
Fiber optic
Inputs 1-8
Outputs 1-8
C
D
Slot 2
IN
IN
OUT
OUT
Fiber optic
Inputs 9-16
C
D
Outputs 9-16
Output 11
Output 12
Slot 3
No board
Input 11
Input 12
installed
Slot 4
E
F
G
H
SDI/HD-SDI
Inputs 25-32
Outputs 25-32
IN
IN
OUT
OUT
Input 30
Input 32
Input 31
OUT
IN
OUT
IN
OUT
IN
A
B
C
RESET
OUT
IN
OUT
IN
OUT
IN
3
1
2
3
A
B
C
OUT
IN
OUT
IN
OUT
IN
4
A
B
C
OUT
IN
OUT
IN
OUT
IN
A
B
C
OUT
IN
OUT
IN
OUT
IN
A
B
C
IN
IN
IN
OUT
OUT
OUT
A
B
C
A
B
C
D
E
F
G
MUTI-RATE SDI INPUTS
2
A
B
D
E
C
F
G
MUTI-RATE SDI INPUTS
REDUNDANT
100-240V
50/60Hz
2A MAX.
PRIMARY POWER SUPPLY
5
PRIMARY
100-240V
50/60Hz
ANAHEIM, CA
2A MAX.
Figure 2-1 — Fiber Matrix 6400 Switcher 1616 rear
panel
a
Fiber optic connectors and LEDs — See page 2-4.
b
SDI/HDI-SDI BNC connectors — See page 2-5.
c
Ethernet connection (LAN connector) — See page 2-5.
d
Remote port — See page 2-5.
e
Power connectors — See page 2-5.
f
Power indicator LEDs — See page 2-5.
Fiber Matrix 6400 Switcher • Installation
Refer also to the Fiber Matrix 6400 Switcher User's Manual at www.extron.com.
1
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
D
E
F
G
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
D
E
F
G
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
D
E
F
G
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
D
E
F
G
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
D
E
F
G
IN
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
D
E
F
G
H
A
B
C
D
E
F
G
MUTI-RATE SDI OUTPUTS
H
A
B
D
C
E
F
G
MUTI-RATE SDI OUTPUTS
REDUNDANT POWER SUPPLY
6
IN
H
IN
H
IN
H
IN
H
IN
H
IN
H
H
H
6
2-3

Advertisement

Table of Contents
loading

Table of Contents