Installation; Filter Location; Filter Plumbing - Pentair FULLFLOXF Q Series Installation And User Manual

Cartridge style d.e. filter
Table of Contents

Advertisement

2

INSTALLATION

The following information describes how to install the
FullFloXF
Q-Series Cartridge Style D.E. Filter. Only a
®
qualified service person should install this filter.
Note: Before installing this product, read and follow
all warning notices and instructions on pages i-ii.

Filter Location

1. The filter should be mounted on a level concrete
slab. Position the filter so that instructions,
warnings and the pressure gauge are visible to the
operator.
2. Position the filter so that the piping connections,
control valve and drain port are convenient and
accessible for servicing and winterizing.
3. Install electrical controls (e.g., on/off switches,
timers, control systems, etc.) at least 5 ft. (1.5 m)
from the filter. This will allow you enough room to
stand clear of the filter during system start up.
4. Allow sufficient clearance around the filter to permit
visual verification that the clamp ring is properly
installed around the tank flanges, see Figure 1.
Note: Refer to the page 7 for instructions on
properly installing the clamp ring.
5. Allow sufficient space above the filter to remove the
filter lid for cleaning and servicing. This distance
will vary with the model of filter you are using. See
Table 1 for the required vertical clearance.
6. Position the filter to safely direct water drainage.
Rotate the HiFlow™ Manual Air Relief Valve to
safely direct purged air or water. Water discharged
from an improperly positioned filter or valve can
create an electrical hazard as well as damage
property.
RISK OF ELECTRICAL SHOCK OR
ELECTROCUTION. Position the filter and
manual air relief valve to safely direct
water drainage and purged air or water.
Water discharged from an improperly
positioned filter or valve can create an
electrical hazard that can cause severe personal injury as well as
damage property.
7. Install the manual air relief valve and pressure
gauge before use. See Installing the Manual Air
Relief Valve on the next page.
XF
®
FULLFLO
Q-SERIES Cartridge Style D.E. Filter Installation and User' s Guide

Filter Plumbing

1. Make all plumbing connections in accordance with
local plumbing and building codes. Check local
codes for restrictions on backwash to waste piping,
separation tank requirements and spent D.E. disposal
requirements.
2. Filter plumbing connections are provided with an
O-ring seal. To avoid damage to the O-rings, use only
a silicone base lubricant on the O-rings. Do not use
pipe joint compound, glue or solvent on the bulkhead
connections.
This D.E. filter has a different water flow
pattern than all other Pentair D.E. filters.
When plumbing the filter with a backwash valve, one of the following
valves, listed below, must be used. Failure to use the correct
backwash valve could damage the filter cartridges and void the
warranty.
3. This filter requires one of the following Pentair
accessories which must be purchased separately.
a. P/N 262511 - FullFloXF Valve (Recommended)
b. P/N 410020 - Union Kit
Table 1
Model
P/N
Q80
188627
Q100
188613
Q120
188616
Figure 1
Vertical
Clearance
Size
Required
80 sq. ft.
65 in.
100 sq. ft.
80 in.
120 sq. ft.
80 in.