Specification
Dimensions and weights
Type
Cylinder capacity
DIN registration no.
Dimensions
Length (
incl. thermal insulation)
7
Overall width with Solar-Divicon (incl. thermal insulation)
Height (incl. thermal insulation)
Height when tilted (incl. thermal insulation)
Weight (with thermal insulation and Solar-Divicon)
Total weight in operation
Heating water capacity
Upper indirect coil
■
Lower indirect coil
■
Heating surface
Upper indirect coil
■
Lower indirect coil
■
Connections
Heating water flow and return
Cold water, DHW
DHW circulation
Solar-Divicon (locking ring fitting/double O-ring)
Product characteristics
Cylinder capacity
Standby heat loss
*1
q
at 45 K temperature differential
BS
V
(standby volume)
aux
V
(solar volume)
sol
Specification with 3-stage solar circuit pump
Grundfos solar circuit pump
Rated voltage
Power consumption at
Output stage I
■
Output stage II
■
Output stage III
■
Flow indicator
Safety valve (solar)
Max. operating temperature
Max. operating pressure
Standard parameter
*1
CVBA
l
mm
mm
mm
1485
mm
1590
kg
kg
l
l
m
2
m
2
R
R
R
mm
l
kWh/24 h
0.89
l
l
V~
W
W
W
l/min
bar
MPa
°C
bar
MPa
Specification
CVBA
250
300
9W271/12-13MC
631
631
860
860
1704
1788
124
134
374
434
6.0
6.0
6.5
6.5
0.9
0.9
1.0
1.0
1
1
1
1
1
1
22
22
250
300
1.79
100
116
150
184
15
65
–
230
50
65
80
2 to 15
6
0.6
120
6
0.6
15